Research by DoINeedAPermit Research Team · Updated May 2026
The Short Answer
Any new heat pump install, replacement of a gas furnace with a heat pump, or supplemental heat pump addition requires a permit from the City of Arvada Building Department. Like-for-like replacements (same tonnage, existing location, same refrigerant type) pulled by a licensed contractor may be processed over-the-counter with minimal delay.
Arvada sits in IECC Climate Zone 5B, which means cold-climate backup heat is mandatory on all heat pump installs under Colorado building code. That requirement — detailed in the International Energy Conservation Code and enforced by Arvada's Building Department — shapes how your system must be designed and inspected. Unlike some Colorado towns that waive permits for straightforward like-for-like replacements, Arvada requires a licensed contractor-filed permit for any system that differs in tonnage, capacity, location, or fuel type. If you're replacing a 40-year-old gas furnace with a new heat pump (even the same 3-ton unit), that's a permit job in Arvada. The city's online permit portal accepts both residential mechanical applications. Arvada's plan-review cycle for HVAC permits is typically 5–7 business days for licensed contractors submitting complete applications; owner-builders may face longer review. The IRA tax credit (30% of equipment cost, up to $2,000) and Colorado utility rebates are tied to permitted, inspected installations — skipping the permit means forfeiting $1,500–$5,000 in incentives.

What happens if you skip the permit (and you needed one)

Arvada heat pump permits — the key details

Arvada Building Department administers mechanical permits under the current International Energy Conservation Code (IECC) and International Residential Code (IRC). For heat pumps specifically, IRC M1305 governs clearances to combustibles (not typically a major issue for electric heat pumps, but matters if backup resistance heat or an emergency gas furnace is present), and IRC E3702 governs the electrical installation of air-source heat pumps. NEC Article 440 applies to the condensing unit outdoor compressor circuit, which is why your electrician must size the disconnect and breaker for the locked-rotor amperage (LRA) of the compressor, not just the running current. Arvada is located in IECC Climate Zone 5B on the Front Range; this cold climate triggers a specific requirement: you must show backup heat on your plans. Colorado code does not allow a heat pump to be the sole heating source. That backup can be electric resistance heating (the air handler's aux heat kit) or, if you're retaining a gas furnace, a dual-fuel arrangement. This is not optional in Arvada — the permit reviewer will reject plans that don't specify how occupied spaces will stay above 60°F if the heat pump cannot meet the design heating load at outdoor temperature extremes. Most residential heat pumps in Arvada hit their minimum operating temperature around -10°F to -15°F (depending on equipment); below that, backup heat activates. The Building Department's permit application requires a completed Manual J load calculation proving the heat pump size is correct for the building's heating and cooling loads. Undersized units are flagged immediately. Licensed contractors typically have these calculations in their systems; owner-builders must hire an HVAC designer or use software (such as Wrightsoft or similar) to run the calc and attach it to the permit.

Refrigerant-line routing is a common rejection point. The distance from the outdoor condensing unit to the indoor air handler cannot exceed manufacturer specs — typically 50–100 feet for residential units, depending on the model and elevation. Arvada is at 5,280–5,400 feet elevation on the Front Range; this matters because refrigerant density and pressure drop increase with line length. If your proposed outdoor unit is more than 75 feet from the indoor unit (common in larger homes), the permit reviewer will ask for a pressure-drop calculation or a pre-approval letter from the equipment manufacturer. Condensate routing is another frequent fail. In Colorado's dry climate, some homeowners assume condensate isn't an issue; in fact, cooling-mode operation in summer (yes, heat pumps cool too) does produce condensate from the indoor coil. Your plans must show where that water drains — typically a ¾-inch PVC line to a floor drain, sump, or daylight. The permit paperwork asks for this detail; if it's missing, the application is incomplete and review is delayed by 5–7 days. Electrical service is also scrutinized. A typical 3-ton air-source heat pump compressor draws 20–30 amps running and 60–80 amps locked rotor. The air handler and backup resistance heat add another 15–20 amps. If your service panel is already at 80% capacity, you may need a panel upgrade before the heat pump is installed. Arvada's Building Department will not issue a final permit if the electrical design shows an overloaded panel. This is a $1,500–$3,000 add-on cost if it's needed.

Arvada is in expansive-soil country — bentonite clay is common in this part of Colorado's Front Range. This doesn't directly affect heat pump installation, but it does affect the outdoor condensing unit's foundation. The unit must be on a level, stable base — concrete pad or similar. If the ground is soft or prone to settling, the refrigerant lines and electrical connections can stress and fail. The permit reviewer may ask for a photograph showing the proposed outdoor location and its existing grade; if you're installing on clay that looks unstable, the inspector will flag it at the rough mechanical inspection. Concrete pads are cheap insurance ($200–$400) and are typically installed as standard practice. Clearing and backfill are also on you; the condenser needs at least 2 feet of clearance on all sides for air circulation and maintenance access (IRC M1305.1.1). If the unit is hemmed in by fencing or landscaping, that's a permit rejection or an enforcement issue at inspection.

Arvada's permit application process is managed through the city's online permit portal. A licensed contractor can submit the complete package (application, load calc, equipment spec sheet, electrical single-line diagram, and condensate routing detail) and typically receive a permit-ready notification within 5–7 days. An owner-builder faces the same process but may encounter longer review windows (7–14 days) if the reviewer has questions or if the designer's calculations are incomplete. The permit fee in Arvada is calculated based on the estimated cost of the work; for a typical residential heat pump (equipment + labor), the valuation is $5,000–$12,000, yielding a permit fee of $150–$400. Once permitted, inspections are mandatory: rough mechanical (before drywall or insulation covers the refrigerant lines and electrical conduit), rough electrical (service-entrance work and panel modifications), and final mechanical and electrical. Each inspection is typically scheduled 24–48 hours in advance; turnaround is 3–5 business days. Total timeline from application to final inspection is 2–4 weeks for a straightforward replacement.

Federal and state incentives are a major financial driver for heat pump installations in Colorado. The Inflation Reduction Act (IRA) provides a 30% tax credit on equipment cost, up to $2,000, for owner-occupied homes. That credit requires a permitted, inspected installation. Many Colorado utilities and the state's Energy Office also offer rebates ($500–$5,000 depending on the program and system efficiency) for ENERGY STAR Most Efficient heat pumps. These rebates also require proof of permitting and inspection. In Arvada specifically, Xcel Energy (the local utility) runs a residential heat-pump rebate program; as of 2024, it offers $500–$1,500 for efficient cold-climate air-source heat pumps. The rebate is triggered by a copy of the final permit and the installer's proof of completion. Skipping the permit means losing all of this money — typically $2,000–$5,000 combined. The permit fee ($200–$300) is effectively a one-time unlock for five- and ten-figure incentive payouts. Licensed contractors in Arvada are well versed in stacking these rebates; owner-builders must research and apply separately, but the incentives are real and significant.

Three Arvada heat pump installation scenarios

Scenario A
Replacing a 30-year-old electric furnace with a 3-ton air-source heat pump, same indoor location, licensed contractor
You have an old electric forced-air furnace in a basement closet in a 1980s split-level in Arvada's Westgate neighborhood. The furnace is still running but inefficient; you want to replace it with a 3-ton AHRI-rated air-source heat pump (like a Lennox XC21 or Trane XV25i). The indoor air handler will occupy the same footprint as the old furnace; the outdoor condenser will go on a concrete pad beside the house, 35 feet from the indoor unit via a basement-run refrigerant line. Because this is a fuel-type change (electric resistance to heat-pump), a permit is required even though the tonnage and location are the same. Your licensed HVAC contractor files the permit application online through Arvada's portal, including a Manual J load calc (which shows the 3-ton unit is appropriate for your 2,100-square-foot home), a one-line electrical diagram showing a 30-amp dedicated circuit for the compressor and a 20-amp circuit for the air handler, and a note that backup resistance heat (the existing electric strip heater in the air handler) will provide auxiliary heating below the compressor's minimum operating temperature. The permit fee is $250 based on a $8,000 estimated job cost. Plan review takes 6 business days; the permit is issued with two inspection points: rough mechanical (after refrigerant lines, condensate drain, and electrical conduit are in place, before drywall patches) and final (after everything is operational and tested). Rough inspection happens 3 days after you call it in; the inspector verifies refrigerant-line clearances (no sharp bends, proper support), condensate routing (¾-inch PVC to the floor drain), and breaker labeling. Final inspection confirms airflow, thermostat operation, and a pressure test of the refrigerant system. Total timeline is 3 weeks from permit issuance to final sign-off. You then submit the permit completion form to Xcel Energy and claim a $750 rebate (their 2024 rate for a cold-climate heat pump) plus the federal 30% IRA credit ($2,400 on a $8,000 equipment cost, capped at $2,000). Out-of-pocket: $8,000 + $250 permit = $8,250; net after incentives: ~$5,500.
Permit required | Manual J load calc required | Licensed contractor (faster review) | Backup resistance heat mandatory | 30-amp compressor circuit + 20-amp air-handler circuit | $250 permit fee | 3-week timeline | Rough + final mechanical/electrical inspections | $750 Xcel rebate + $2,000 IRA credit
Scenario B
Adding a supplemental mini-split heat pump to a bedroom suite, gas furnace retained in main house, owner-builder
Your master bedroom suite is always cold in winter; the main gas furnace in your Arvada home can't keep the room above 65°F without overheating the rest of the house. You decide to add a single-zone mini-split heat pump (9,000 BTU, AHRI-rated, wall-mounted indoor head) to the suite, with the outdoor condenser on a pad in the backyard. This is a supplemental heat pump added to an existing dual-fuel system (gas furnace + new electric heat pump). Technically, it's an addition, not a replacement, so a permit is mandatory. You're owner-builder, so you hire an HVAC designer to run a Manual J and produce sealed plans; you also hire a licensed electrician for the electrical work. The designer's plans show the mini-split's 15-amp 240V dedicated circuit, the refrigerant line run (50 feet, within manufacturer spec), condensate drain, and a note that the gas furnace remains the primary heating source with the mini-split as backup/zone comfort. The Building Department's plan reviewer questions whether the mini-split's backup heat is defined (it isn't — mini-splits typically have electric resistance coils, but the plan doesn't specify capacity). You resubmit with a spec sheet confirming the unit's 1.5-kW aux heat; plan review is completed on day 8. Permit fee is $180 (based on a $5,500 equipment + labor estimate). Inspections: rough electrical (after breaker installation and conduit placement), rough mechanical (after refrigerant lines are charged and condensate routing is visible), and final (thermostat operation, wireless signal strength if the unit is zoned). Because you're owner-builder, the inspector is slightly more thorough; each inspection takes 20–30 minutes. Total timeline: 3.5 weeks. Federal IRA credit applies ($1,650 on a $5,500 cost, capped at $2,000), and you may qualify for a Colorado utility rebate of $300–$500 (mini-splits are sometimes excluded from the main rebate; check your utility). Out-of-pocket: $5,500 + $180 permit + $300 designer + $800 electrician = $6,780; net after $1,650 IRA credit: ~$5,130.
Permit required (supplemental system) | Owner-builder (longer review) | HVAC designer + sealed plans required | Manual J calc for zone sizing | 15-amp 240V dedicated circuit | Refrigerant line 50 feet (within spec) | Condensate drain to daylight | $180 permit fee | Rough electrical + mechanical + final inspections | 3.5-week timeline | $1,650 IRA tax credit (mini-splits often exclude utility rebates)
Scenario C
Like-for-like replacement: 3-ton air-source heat pump to new 3-ton unit, existing location, existing refrigerant type (R-410A), licensed contractor
Your 10-year-old Carrier heat pump (3 tons, R-410A refrigerant) is losing refrigerant and failing to cool. A licensed HVAC contractor quotes a replacement with an identical Carrier model (same tonnage, same outdoor location, same indoor air-handler location, same refrigerant type). Strictly speaking, this is a like-for-like replacement and could be processed as a simple service call in many Colorado jurisdictions. However, Arvada's Building Department typically requires a permit even for like-for-like replacements involving a full system swap (the old unit is removed and a new unit is installed in its place). The reason: the inspector wants to verify that the outdoor pad is still level and stable (bentonite clay shifts), that the refrigerant lines are not damaged or undersized, and that the electrical disconnect is properly labeled and breaker-sized for the new compressor (even if it's the same tonnage, a newer model may have different LRA specs). The contractor submits a one-page permit application (often an over-the-counter form) with the equipment spec sheet. No Manual J is required because the tonnage is unchanged. No electrical single-line is needed because the circuit is existing. Plan review is 1–2 days, and the permit is issued immediately (same-day, often). Permit fee is $100–$150 (flat fee for like-for-like replacements in Arvada, or a reduced valuation-based fee). The contractor schedules a rough mechanical inspection (refrigerant-line integrity, outdoor pad condition, compressor disconnect label) and a final inspection (system operation, pressure test). Total timeline: 5–7 business days from permit issuance to final sign-off. Because this is a like-for-like replacement, the federal IRA credit does NOT apply (the credit requires a heat pump to replace a fossil-fuel heating system or be a new installation, not a same-for-same upgrade of an existing heat pump). However, some utilities do offer small rebates ($100–$300) for high-efficiency units even on replacements; check Xcel Energy's 2024 program. Out-of-pocket: $5,000–$7,000 (new unit) + $100–$150 permit + $800–$1,200 labor = $5,900–$8,350. No tax credit, but possible $100–$300 rebate.
Permit required (full replacement, even like-for-like) | No Manual J required (same tonnage) | No electrical redesign required | Over-the-counter form (fast) | Equipment spec sheet only | $100–$150 permit fee | Same-day permit issuance | Rough mechanical + final inspection only | 5-7 day timeline | No federal IRA credit (same-system upgrade) | Possible $100–$300 utility rebate

Every project is different.

Get your exact answer →
Takes 60 seconds · Personalized to your address

Cold-climate backup heat requirements in Arvada (IECC Zone 5B)

Arvada sits in IECC Climate Zone 5B, classified as cold. This means the International Energy Conservation Code explicitly requires that any air-source heat pump installed in Arvada must have a documented backup heating source and a control strategy that activates that backup when the heat pump cannot meet the design load. The reason: air-source heat pumps lose capacity as outdoor temperature drops, and in a cold climate, the outdoor design temperature (the 99th percentile worst-case winter day in Arvada, typically around -10°F) will drop below the heat pump's minimum operating temperature. Most residential air-source heat pumps shut down or dramatically reduce capacity below -10°F to -15°F. Without backup heat, a home can fall to uninhabitable temperatures. Colorado's Building Department enforces this via the IECC compliance pathway, and Arvada's Building Department applies this rule stringently.

The backup heat must be either electric resistance (an aux heat kit installed in the air handler, typically 5–10 kW) or a dual-fuel arrangement where a gas furnace provides auxiliary heating. On your permit application, you must specify which backup method you're using and confirm that the thermostat or control board is programmed to switch to backup when the outdoor temperature falls below the heat pump's rated minimum or when the indoor temperature drops 2°F below setpoint (a sign the heat pump can't keep up). The Building Department's plan reviewer will ask to see the thermostat's control logic in the spec sheet or installation manual. If it's missing, the application is incomplete and review is delayed. Most licensed contractors include aux heat as standard; owner-builders sometimes overlook this and face a plan rejection.

In practice, backup heat in Arvada activates during winter cold snaps (December–February) and is very cost-effective: electric resistance at an average Colorado utility rate of $0.14 per kWh costs about $7–$10 per day to run continuously, which is less than a gas furnace and far more efficient than the old all-electric heating many older Arvada homes have. A heat pump + aux heat system uses backup only during the coldest nights; most winter heating is done by the heat pump, which is 2–3 times more efficient than resistance heat. In IECC 5B, backup heat is not optional — it's a code requirement and a practical necessity.

Federal IRA tax credit (30%, up to $2,000) and Arvada-area utility rebates

The Inflation Reduction Act (IRA), passed in 2022, offers a 30% tax credit on the cost of a qualified air-source heat pump, up to $2,000 per household per year, for owner-occupied homes. The credit applies to both new installations and replacements of fossil-fuel heating systems. For Arvada homeowners, this is a major financial incentive: a $6,000 heat-pump system qualifies for a $1,800 credit (30% of $6,000, since the cap is $2,000); a $7,000+ system caps at $2,000. The credit is non-refundable, meaning it reduces your federal income tax liability, not a direct payment. You claim it on IRS Form 5695 when you file taxes for the year the system was installed. The critical requirement: the installation must be permitted and inspected. The IRS does not explicitly require a copy of the permit in the tax file, but the credit summary refers to 'qualified energy property,' and a permitted, inspected installation is the only way to prove the equipment is installed per code and by a qualified installer (or a homeowner who pulled a permit and passed inspection). Many people ask, 'Can I skip the permit and still claim the credit?' The answer is legally risky: without a permit, you cannot prove the installation meets code or is eligible. An audit would find no supporting documentation.

Xcel Energy, which serves most of Arvada, runs a residential heat-pump rebate program. As of 2024, the rebate is $500–$1,500 depending on equipment efficiency and whether the unit is ENERGY STAR Most Efficient (a certification that indicates the top-15% most efficient models for that capacity). The rebate is claimed by submitting a copy of the final permit, the equipment spec sheet (with AHRI certificate number), and proof of installation (invoice from the contractor or a photo of the final system). Processing takes 4–6 weeks, and the rebate is issued as a check or utility credit. Mini-split heat pumps may have lower rebates or be excluded; check Xcel's current program. The rebate is stacked on top of the federal credit, so a $7,000 system can yield $2,000 (federal) + $1,500 (Xcel) = $3,500 in incentives, bringing net cost to $3,500. This stacking is allowed and intentional. Many homeowners don't realize the rebate exists or forget to apply for it; losing it is a common regret. Arvada's Building Department does not administer the rebate, but the permit is the gating requirement. A few other Colorado utilities and the state's Energy Office run their own programs; if you're on a different utility, verify eligibility before installing.

City of Arvada Building Department
Arvada, CO (contact Arvada City Hall for specific building-permit office address and hours)
Phone: (720) 898-7303 (Arvada Community Development Department — confirm direct building-permit line) | https://www.arvada.org (search 'permits' or 'online permit portal' on the city website)
Monday–Friday, 8:00 AM–5:00 PM (verify locally before visiting; some offices close mid-day)

Common questions

Can I install a heat pump myself in Arvada without a permit?

No. Any new heat pump installation, supplemental addition, or replacement of a gas furnace with a heat pump requires a permit from the City of Arvada Building Department. Owner-builders are allowed to pull permits for owner-occupied 1–2-family homes in Colorado, but the permit is mandatory. If you install without a permit, the city can issue a stop-work order, fine you $500–$1,500, and require you to remove the system or pay double fees to legalize it retroactively. You also forfeit federal IRA tax credits and utility rebates, losing $2,000–$5,000 in incentives.

What is a Manual J load calculation, and do I need one for my heat pump permit in Arvada?

A Manual J is an HVAC industry-standard calculation that determines the heating and cooling load of your home based on square footage, insulation, window area, occupancy, and local climate. It proves that your chosen heat pump tonnage is correct — not oversized (wastes money and cycles on/off too frequently) and not undersized (can't keep up on cold days). Arvada's Building Department requires a Manual J for any new or replacement heat pump installation. Licensed contractors typically have these calculations in their software or can complete one in an hour ($100–$200); owner-builders can hire an HVAC designer or use cloud-based software (Wrightsoft, Manual J Online) to complete one and attach it to the permit application. Without a Manual J, the permit application is rejected as incomplete.

Does Arvada require a permit for a like-for-like heat pump replacement (same tonnage, same location)?

Yes, Arvada typically requires a permit even for like-for-like replacements where you're removing an old heat pump and installing a new one of identical tonnage in the same location. The permit is streamlined (over-the-counter, 1–2 day review) and the fee is lower ($100–$150), but it is required. The reason: the inspector verifies that the outdoor pad is stable, refrigerant lines are intact, and the electrical disconnect is correctly sized for the new compressor. If you're only replacing the compressor or motor within an existing heat pump unit (rare), that's generally considered a service call and not permitted. If you're upgrading to a different tonnage or a different type (air-source to mini-split, for example), a full permit with Manual J is required.

What is backup heat, and why does Arvada require it for heat pumps?

Backup heat is a secondary heating source (electric resistance coils in the air handler or a gas furnace) that activates when an air-source heat pump cannot meet the home's heating demand — typically on very cold winter days when the outdoor temperature drops below the heat pump's minimum operating temperature, usually around -10°F to -15°F. Arvada is in IECC Climate Zone 5B (cold climate), and the building code mandates backup heat because the design heating load (the worst-case winter day in Arvada) can require more heat than the heat pump can provide at extreme cold. Without backup, homes would become dangerously cold. Most heat-pump systems in Arvada use electric resistance as backup (via an aux heat kit) because it's simple, works well with the thermostat control logic, and is cost-effective for the few nights per year it's needed. If you're retaining a gas furnace and adding a heat pump as the primary heating source, dual-fuel with the furnace as backup is also acceptable.

How much does a heat pump permit cost in Arvada?

Permit fees in Arvada are based on the estimated cost of the work (equipment + labor). For a typical residential heat pump installation ($5,000–$12,000 estimated cost), the permit fee is $150–$400. Like-for-like replacements may qualify for a flat fee of $100–$150. The fee is not refundable if you decide not to proceed, but it covers the permit, plan review, and two inspections (rough and final). On top of the permit fee, you'll pay for the equipment, labor, electrical work (if a new circuit or panel upgrade is needed), and potentially a Manual J load calculation ($100–$200 if not included by your contractor). Always confirm the fee with Arvada's Building Department before submitting; fees change annually.

Will I lose my federal tax credit if I don't get a permit for my heat pump?

Yes, practically speaking. The IRA tax credit requires installation of a 'qualified heat pump' per the Department of Energy specifications and IRS guidance. While the IRS doesn't explicitly require a copy of the permit in your tax file, claiming the credit for an unpermitted system is legally risky. If audited, you would need to prove the system meets code and was installed per manufacturers' guidelines. A permitted, inspected installation provides that proof. More importantly, many installers and tax professionals will not sign off on a credit claim for unpermitted work. Losing the credit ($1,500–$2,000) is far more costly than the permit fee ($150–$400).

How long does it take to get a heat pump permit in Arvada?

For a licensed contractor with a complete application, plan review takes 5–7 business days; once the permit is issued, inspections (rough and final) are typically scheduled within 2 weeks, bringing total timeline to 3–4 weeks from application to final sign-off. For an owner-builder or a complex project (e.g., electrical service upgrade required), plan review may take 7–14 days, extending the total timeline to 4–5 weeks. Expedited review is not typically available, but over-the-counter permits (simple like-for-like replacements) can be issued same-day. Call the Building Department before submitting to confirm current timeline expectations.

Do I need to hire a licensed electrician for the heat pump electrical work, or can I do it myself?

In Colorado, homeowners on an owner-occupied property can pull their own electrical permits and do some electrical work themselves if they obtain an owner-builder electrical permit. However, for a heat pump, the electrical code (NEC Article 440) is technical: it requires a dedicated 15–30 amp 240V circuit with a correctly sized breaker (calculated to the compressor's locked-rotor amperage, not just running current), a properly rated disconnect, and correct conduit sizing. Most homeowners lack the expertise, and a mistake can cause a fire or electrocution. It's safer and simpler to hire a licensed electrician, who will pull the electrical permit as part of the HVAC permit package, ensuring code compliance. The electrician's cost ($800–$1,200 for a typical installation) is well worth the liability protection. Many homeowners' insurance policies exclude coverage for unpermitted or non-code-compliant electrical work.

Does Arvada's expansive-soil issue affect heat pump installations?

Indirectly. Arvada's Front Range soil often contains bentonite clay, which expands when wet and shrinks when dry, causing differential settlement. The outdoor condensing unit must be on a stable, level concrete pad (4–6 inches thick, per HVAC best practices). If the pad shifts or settles unevenly, the refrigerant lines and electrical connections can stress and crack, causing leaks and system failure. The permit inspector will look at the outdoor location and may ask for a photo showing existing grade and proposed pad placement. If the ground looks unstable, the inspector may require a level concrete pad or backfill to ensure stability. A standard concrete pad costs $200–$400 and is cheap insurance against future damage. Avoid placing the unit on bare soil or mulch; a pad is standard practice in Colorado.

What if my air conditioner condenser (from an existing heat pump or AC system) is already in the backyard? Can I just replace the compressor instead of the whole unit?

If the outdoor condenser is a heat pump, replacing only the compressor (called a 'compressor change-out') is a repair that typically does not require a permit — it's treated as a service call. However, if you're replacing the entire outdoor unit and indoor air handler with a new heat pump system, that is a permit-level installation. The distinction matters: a $2,000 compressor swap during maintenance is unpermitted; a $7,000 system replacement is permitted. The Building Department's stance is that a full system replacement requires verification that the new equipment meets code, loads are correct, and electrical circuits are sized appropriately. If you're unsure whether you're doing a compressor change-out or a full replacement, ask your contractor or call the Building Department for clarification.

Disclaimer: This guide is based on research conducted in May 2026 using publicly available sources. Always verify current heat pump installation permit requirements with the City of Arvada Building Department before starting your project.