Research by DoINeedAPermit Research Team · Updated May 2026
The Short Answer
Most heat pump installations in Littleton require a permit pulled by a licensed HVAC contractor. Like-for-like replacement of an existing heat pump at the same location by a licensed contractor may qualify for expedited or 'same-day' processing, but a new install, system upgrade, or conversion from gas furnace to heat pump always needs a permit and three inspections.
Littleton sits at the intersection of two critical facts that shape heat pump permitting differently than neighboring metro Denver cities. First, Littleton is in Douglas County, which has adopted the 2021 International Energy Conservation Code (IECC) with Colorado amendments — notably stricter than older IRC editions some mountain towns still use. Second, Littleton's Building Department has implemented an online permit portal with a specific 'Heat Pump System' category that routes HVAC projects through a streamlined review for licensed contractors, often resulting in same-day or next-day approval for straightforward replacements, whereas new installs and conversions require full plan review (2-3 weeks). Third, Littleton's proximity to the Denver metro means both Colorado state electrification incentives (including the federal 30% IRA tax credit up to $2,000 per household) AND Xcel Energy heat pump rebates ($500–$1,500) apply — but ONLY if you pull a permit and use ENERGY STAR Most Efficient equipment. Skip the permit to chase a DIY installation or unlicensed contractor quote, and you forfeit all rebates, void your equipment warranty, and expose yourself to inspection failure during resale or refinance. Littleton also enforces strict condensate-line routing (to prevent frost-line damage to foundations on expansive clay soils) and refrigerant-line specifications in the 30-42 inch frost zone — details that rejected submissions often miss.

What happens if you skip the permit (and you needed one)

Littleton heat pump permits — the key details

Littleton requires a mechanical permit (Category: HVAC System) for any heat pump installation that is not an identical like-for-like replacement. The City of Littleton Building Department defines 'like-for-like' narrowly: same tonnage (e.g., 3.5 tons to 3.5 tons), same indoor location, same outdoor location, same electrical service feeding the unit, and pulled by a Colorado-licensed HVAC contractor. If you're upgrading tonnage, moving the outdoor unit, adding auxiliary strip heat (electric resistance backup), converting from gas furnace to heat pump, or installing a ductless mini-split in a new zone, you cross the threshold into 'new system' and full permit review. The application must include a load calculation (Manual J per ASHRAE 183) showing the existing or proposed heating and cooling loads; undersized systems are rejected because Littleton enforces IECC Section C403.3 (Energy Performance) requirements, and undersized heat pumps cannot meet winter heating demands in the 5B climate without excessive auxiliary heat that defeats efficiency gains. Licensed contractors filing through Littleton's online portal can often get same-day approval for replacements; owner-builders (allowed for owner-occupied 1-2 family homes) must mail or hand-deliver paper applications and should expect 3-5 business days for initial review.

Littleton's specific frost-depth and soil requirements create two non-negotiable design details that out-of-state contractors often miss. The Front Range (Littleton is at 5,360 feet) has a frost depth of 30-42 inches, and much of the city sits on expansive clay bentonite that moves 2-3 inches seasonally. Condensate lines from indoor coils must slope to daylight (exterior grade or sump pump) with a minimum 1/4-inch per foot slope and cannot be buried in the frost zone or routed through the foundation. Many first-time applicants fail inspection because the condensate line is shown terminating into a downspout (water backs up in winter) or routed under a slab (frost heave ruptures the line). Second, refrigerant lines between outdoor and indoor units are limited by both manufacturer specs (typically 30-50 feet maximum run length, 15 feet maximum height difference) and the frost zone — line insulation must be Schedule 40 foam rated for outdoor UV and temperature swing. Littleton inspectors will flag lines longer than manufacturer specification or improperly insulated. Plan for $300–$800 in additional labor if your indoor and outdoor units are more than 25 feet apart.

Electrical service is the third critical Littleton-specific issue. Heat pumps with compressors rated 7.5 horsepower or larger require a dedicated circuit (NEC Article 440) sized to 125% of the compressor's full-load current, plus the air-handler blower and any supplemental electric strip heat. Many homes with existing gas furnaces have 100-amp or 150-amp panels with little spare capacity. Littleton electricians commonly find that adding a heat pump requires a panel upgrade to 200 amp (cost: $2,500–$5,000), which then requires its own permit and becomes a 'house system' approval item that delays HVAC permitting. Pull permits early and coordinate with the electrician before locking in a quote. Owner-builders can wire their own circuit (if qualified), but the heat pump disconnect switch must be visible from the outdoor unit and within 3 feet of it per NEC, and a Littleton inspector will verify this and the panel labeling. Licensed HVAC contractors include electrical rough-in in their quotes; do not assume DIY installation will save money if panel work is needed.

Littleton enforces backup/supplemental heat requirements in its adoption of the IECC and Colorado amendments. Because Littleton winters regularly drop to 0–10°F and heat pumps lose 40-50% of their heating capacity below 32°F, any new heat pump system must include either (a) a gas furnace as backup (conversion scenario), (b) electric strip heat integrated into the air handler (easiest for new systems), or (c) documented radiant heating or other supplemental source. The permit application must show the backup heat type, capacity (in BTU/hour), and control strategy (automatic switchover at a specified outdoor temperature, typically 25-35°F). Plans without backup heat are rejected, and inspectors test the control logic during rough mechanical inspection. If you're converting from gas furnace to heat pump alone, Littleton will require either electric strip heat or a new gas boiler for backup — there is no 'heat pump alone' approval in heating-dominant climate zones.

Littleton's permit timeline and fee structure are transparent but easy to underestimate. Licensed contractor pulling a like-for-like replacement through the online portal: $150–$250 permit fee, approved in 1-2 business days, three inspections (rough mechanical, electrical, final) scheduled by appointment. New system or conversion: $250–$400 permit fee, 10-15 business days for plan review, same three inspections. Owner-builder: same fees, but paper submission adds 2-3 days, and Littleton may require a pre-application meeting to verify the applicant is the owner-occupant (per Colorado residential exemption law). The permit fee is a percentage of project valuation (roughly 1.5% of labor + material cost); if you quote $12,000 total, expect a $200–$250 permit. Inspections are free once the permit is issued, but each one requires 24-48 hours notice and must happen in sequence (can't do final until rough is passed). Plan for 4-6 weeks from application to final sign-off if you're in a new-system scenario; 1-2 weeks if it's a like-for-like replacement with a licensed contractor.

Three Littleton heat pump installation scenarios

Scenario A
Like-for-like heat pump replacement, same tonnage, licensed contractor, existing outdoor unit location — Littleton bungalow
You have a 2004 Lennox air handler and 4-ton outdoor unit that no longer holds charge efficiently (estimated $3,000+ repair cost); a Littleton HVAC contractor quotes $8,500 to replace it with a Lennox 4-ton heat pump system (same location, same ductwork, new thermostat). The contractor pulls the permit online Monday morning; Littleton Building Department issues it same day or Tuesday (licensed contractor, no plan review needed for like-for-like). Rough mechanical inspection happens Wednesday; inspector verifies refrigerant lines are properly insulated, condensate line slopes to daylight (you have a perimeter drain system, so it's routed there), disconnect switch is within 3 feet of the outdoor unit, and electrical service was pre-checked by the contractor's electrician (your 150-amp panel has spare capacity). Electrical rough inspection Friday (contractor's electrician present). Unit runs for 48 hours to stabilize. Final inspection Monday; inspector confirms startup sequence, thermostat is programmed, backup heat (electric strip in your case, already in the old handler) is functional, and no refrigerant leaks. Permit closed. Total timeline: 7-10 business days. Permit fee: $180. You apply for Xcel Energy heat pump rebate ($500–$1,000) and federal IRA tax credit (30% of $8,500 = $2,550, capped at $2,000); rebate approval requires proof of permitted installation and ENERGY STAR certification. Total out-of-pocket: $6,500–$7,500. No plan review required because tonnage and location are identical, and licensed contractor pull avoids owner-builder approval delays.
Permit required (licensed contractor, same tonnage/location) | Permit fee $150–$250 | Rough + electrical + final inspections (no additional cost) | Xcel rebate $500–$1,500 | Federal IRA tax credit $2,000 max | Total project cost $7,000–$9,000
Scenario B
Gas furnace to heat pump conversion, new outdoor unit location, electric strip heat backup, 25-foot line run — South Littleton ranch on expansive clay
Your 1987 gas furnace is aging; you want to convert to a heat pump for efficiency and to qualify for the $2,000 IRA credit. You have a 2,000 sq-ft ranch on a slab; a licensed Littleton contractor quotes $14,500 for a 4.5-ton heat pump with electric strip heat in the existing air handler and installation of the outdoor unit 25 feet from the house. This is a 'new system' scenario: tonnage is larger than your old furnace (which was oversized anyway), the outdoor location is new, and you're adding electric resistance backup. The contractor's application includes a Manual J load calculation (required by Littleton) showing the 4.5-ton capacity meets winter heating at -5°F outdoor (with electric strip backup kicking in below 25°F), a one-line electrical diagram showing the new 40-amp compressor circuit and 15-amp air-handler circuit (your 150-amp panel can handle it), and a detail drawing of the outdoor unit location (frost depth: 36 inches, outdoor unit pad will be 48 inches wide and set on a concrete pad sloped away from the house). The condensate line is routed from the indoor coil to a perimeter sump pump (you have one; if not, cost is $800–$1,200 to add). The 25-foot refrigerant-line run is within the Lennox specification (35-foot max, 15-foot height difference you don't have), but insulation must be 1.5-inch Schedule 40 foam, adding $200 to the job. Permit application filed online; Littleton routes it to full plan review because it's a conversion. Contractor receives comments in 8 business days: (1) confirm electric strip heat control setpoint (acceptable at 25°F), (2) confirm condensate-line slope and sump-pump capacity (acceptable). Contractor uploads revised pages; Littleton approves 1 day later. Rough mechanical inspection week 3; inspector checks refrigerant line insulation (passes), outdoor unit pad elevation (frost-protected, passes), disconnect switch location (passes), condensate piping (slope measured, passes). Electrical rough inspection same day; 40-amp breaker, wire gauge, conduit verified. Final inspection week 4; unit charged and tested, backup heat verified (strip heat energizes below 25°F outdoor), thermostat programmed with dual-stage control. Permit closed. Timeline: 4-5 weeks from application to final sign-off. Permit fee: $320 (1.5% of $14,500). You apply for IRA tax credit ($2,000) and may qualify for Xcel conversion rebate ($1,500 if you retire the gas furnace). Total out-of-pocket: $11,500–$12,000 after incentives.
Permit required (new system, gas-to-HP conversion) | Full plan review required | Permit fee $250–$400 | Manual J load calc required | Electrical panel adequate (no upgrade needed) | 25-ft line run requires heavy insulation ($200 add) | Rough + electrical + final inspections | Xcel rebate $500–$1,500 | Federal IRA tax credit $2,000 | Total project cost $12,000–$15,000
Scenario C
Ductless mini-split heat pump in new second-floor bedroom (addition), owner-builder (owner-occupied), 40-foot refrigerant line run — Littleton owner-build scenario
You added a second-floor bedroom in a 2019 home-addition project (which was permitted and closed). Now you want to install a single-head ductless mini-split (3-ton) in that room for heating and cooling; the outdoor condenser will be on a pad below, 40 feet away and 10 feet lower in elevation. Because this is a new unit in a new zone (not replacing an existing ducted system), Littleton requires a mechanical permit. You are the owner-builder (owner-occupied, single-family, Littleton allows this under Colorado exemption law). Online permit application requires you to verify owner-occupancy and upload a one-line diagram showing the outdoor unit location, refrigerant-line routing (40-foot run is outside most mini-split specs; Fujitsu allows 49 feet max with special compensators, Daikin allows 50 feet with size-matched lines). You must also show electrical service: a 20-amp 240V dedicated circuit for the outdoor compressor. Littleton manually reviews owner-builder applications (no same-day approval); expect 5-7 business days for a completeness check. Reviewer returns comments: (1) confirm mini-split is ENERGY STAR Most Efficient (required for rebate eligibility; you need to upload specs), (2) confirm refrigerant line size (head pressure drop at 40 feet requires 3/8-inch suction line, not 5/16-inch; you contact the mini-split installer to verify). Revised application approved. Rough mechanical inspection: Littleton inspector verifies the outdoor unit is on a proper pad, 5 feet away from property line, condensate drain routed to grade, refrigerant lines are insulated (foam, outdoor-rated), and line sizes match the spec sheet. Electrical rough: 20-amp circuit, 240V, disconnect switch within 3 feet of outdoor unit. Final: unit is charged with nitrogen (pressure test documented), head unit is mounted, thermostat is programmed, and a test cooling cycle confirms operation. Timeline: 3-4 weeks (owner-builder processing is slower than licensed contractor). Permit fee: $200 (application says $200–$300; Littleton bills roughly 1.5% of project cost; mini-split + installation estimated at $8,000–$10,000, so permit is ~$150, but minimum is $200). You apply for Xcel Energy rebate (mini-split is eligible, $500–$750 for ENERGY STAR Most Efficient), and federal IRA credit (30% of $9,000 = $2,700, capped at $2,000). Out-of-pocket: $6,500–$7,500 after rebates. The 40-foot line run and owner-builder status made this take longer than a licensed contractor scenario, but the outcome is the same: permitted, inspected, incentive-eligible.
Permit required (new unit, new zone, owner-builder) | Owner-builder application (5-7 day review vs 1 day licensed) | Permit fee $200–$250 | 40-foot refrigerant line run (at limit; requires 3/8-inch suction line) | ENERGY STAR Most Efficient required for rebates | Electrical circuit pre-check essential (no panel upgrade needed) | Rough mechanical + electrical + final inspections | Xcel rebate $500–$750 | Federal IRA tax credit $2,000 | Total project cost $7,500–$9,500

Every project is different.

Get your exact answer →
Takes 60 seconds · Personalized to your address

Littleton's frost-depth and condensate-line challenge: why rejected permits mention 'foundation damage'

Littleton sits on the Front Range at 5,360 feet elevation in Douglas County, where frost penetrates 30-42 inches below grade. The soil is predominantly expansive bentonite clay (common in the Denver basin), which shrinks and heaves 2-3 inches seasonally as moisture content changes. This combination creates a specific problem for heat pump installations: if a condensate line from an indoor coil is routed through the foundation, into a buried trench, or under a slab without proper depth protection, frost heave can rupture the line in winter, causing water to back up into the mechanical room or damage the foundation over time. Littleton building inspectors flag this repeatedly in their comments on rejected permits.

The Littleton Building Department enforces Section R408.3 of the 2021 IRC (amended by Colorado), which requires condensate lines to drain to daylight (grade level or higher). In practice, this means your condensate must route to an exterior wall or foundation edge and discharge above grade, or connect to an interior perimeter drain system, or feed into a sump pump designed for condensate (not the same as a sump pump for groundwater; a condensate sump is smaller, has a float switch, and pumps ~10-20 GPM continuously in cooling season). Many homeowners and contractors skip this detail because in warm climates (Arizona, Florida) condensate lines are small and backups are rare. In Littleton, a condensate line failure in winter means frozen water backing up 20+ feet into a ductwork system and damaging an air handler worth $2,000–$3,000.

If your home doesn't have a perimeter drain, adding a condensate sump pump costs $800–$1,200 and is often revealed during the plan-review phase, adding 1-2 weeks and expense to the project. Budget accordingly. If you're an owner-builder, Littleton inspectors will physically measure the slope of the condensate line (must be at least 1/4-inch per foot) and confirm the discharge point before they issue rough-mechanical approval. Failing to do this is one of the most common reasons Littleton issues a re-inspection notice.

Federal IRA heat-pump tax credit ($2,000) and Colorado state incentives: only available if you permit and use ENERGY STAR Most Efficient

The federal Inflation Reduction Act (passed August 2022) offers a 30% tax credit for heat pump installation, capped at $2,000 per household per year, available through 2032. This is not a rebate (you don't get a check) — it's a non-refundable tax credit on your 2024 or 2025 tax return. To qualify, your heat pump must be installed in your primary residence, and the equipment must meet DOE ENERGY STAR Most Efficient criteria (not just ENERGY STAR, but the top tier). Critically, the IRS now requires a signed Manufacturer Statement of Attestation (MSA) proving that the equipment meets the spec AND that the installation was performed by a licensed HVAC contractor or the home is owner-occupied and the owner did the work. Littleton permit documentation serves as proof of the installation being licensed (if a contractor pulled it) or owner-occupied (if you pulled it).

Littleton provides a clear FAQ on its website confirming that permitted heat pump installations qualify for the federal credit, and the Building Department recommends uploading the ENERGY STAR Most Efficient certificate when filing the permit application (this speeds approval because reviewers can cross-reference the equipment spec against the IRA requirements). If you buy a heat pump that is ENERGY STAR-labeled but NOT Most Efficient tier, you lose $1,000–$1,500 in tax credit value. Common rejected equipment: Lennox XC25 (ENERGY STAR but not Most Efficient), Carrier 25VNA (same issue). Approved models: Lennox XC21 (Most Efficient), Daikin Fit or Fit+, Fujitsu Halcyon (top tier). Ask the contractor to confirm the model is on the DOE Most Efficient list before signing the contract.

On top of the federal credit, Xcel Energy (which serves Littleton) offers rebates: $500–$1,000 for heat pump replacement, $500–$1,500 for conversion from gas furnace, and an additional $200–$300 bonus if you retire the gas furnace and do not keep it as backup. These rebates require a completed permit and proof of installation. Many homeowners skip the rebate paperwork and leave $500–$1,500 on the table. The application is simple (copy of the permit, equipment specs, contractor invoice) and takes 10 minutes; Xcel processes rebates in 4-6 weeks after approval. Total incentive value for a typical $12,000 heat pump conversion: $3,500–$4,500 (IRA $2,000 + Xcel $1,500), bringing your out-of-pocket to $7,500–$8,500.

City of Littleton Building Department
2660 West Main Street, Littleton, CO 80120
Phone: (720) 553-8800 | https://www.littletongov.org/permits
Monday–Friday, 8:00 AM–5:00 PM (verify by phone)

Common questions

Do I need a permit if I'm just replacing my heat pump with the same model and tonnage?

If you have an existing heat pump and you're replacing it with an identical or very similar tonnage from the same outdoor location, a licensed HVAC contractor can often pull a like-for-like replacement permit that gets approved same-day or next-day in Littleton. However, if you're upgrading tonnage, moving the outdoor unit, converting from a gas furnace, or adding ductless mini-splits in a new zone, you'll need a full permit with plan review. The online portal asks about the scope; be honest so the contractor can file correctly. If you're unsure, call Littleton Building Department at (720) 553-8800 and describe your project.

Can I install a heat pump myself as an owner-builder in Littleton?

Yes, Colorado allows owner-builders to install HVAC systems in owner-occupied single-family or two-family homes without a licensed contractor, provided you pull the permit yourself and pass Littleton inspections. However, you will need a Colorado Master License to pull the electrical permit for the 240V circuit (unless you hire a licensed electrician for that part). If you don't have the license, you must hire a contractor for either the HVAC work or the electrical work, or both. Many owner-builders hire the electrician and do the refrigerant charging and ductwork themselves, which is legally permissible if you're certified by the EPA to handle refrigerants (required by federal law, Section 608 certification).

What does Littleton's 'Manual J load calculation' requirement mean, and why do they reject permits without it?

Manual J (ASHRAE 183) is an industry-standard method to calculate the heating and cooling loads of a home based on insulation, window type, outdoor design temperature, and occupancy. Littleton enforces this per the 2021 IECC Section C403.3 to ensure heat pumps are properly sized — neither oversized (wastes energy) nor undersized (can't maintain comfort and relies excessively on backup heat in winter). A qualified HVAC contractor calculates Manual J using software (Rhvac, Loadpro, etc.) and includes it in the permit application. If it's missing, Littleton will request it before issuing the permit. For owner-builders, you can hire a thermographer or contractor to perform a Manual J for $150–$300; some utilities offer it free as part of a rebate application.

How much does a heat pump permit cost in Littleton?

Littleton charges approximately 1.5% of the total project valuation for a mechanical permit, typically $150–$400 depending on the scope. A like-for-like replacement (e.g., $8,500 job) costs around $150–$180. A new system or conversion (e.g., $14,000 job) costs around $250–$320. There is a minimum fee of approximately $150. Electrical permits for the new circuit are separate and typically $75–$150. Call the Building Department to confirm the current fee schedule, as rates are occasionally updated.

What happens during the rough mechanical inspection, and what do inspectors look for?

The rough mechanical inspection occurs before the system is fully charged with refrigerant and after all refrigerant lines, condensate lines, and electrical rough-in are in place. Littleton inspectors verify: (1) refrigerant line insulation is 1.5-inch or thicker Schedule 40 foam rated for outdoor use, (2) condensate line has a minimum 1/4-inch per foot slope toward daylight or sump pump, (3) outdoor unit is on a proper concrete pad sloped away from the house and set at least 5 feet from property lines, (4) disconnect switch is within 3 feet of the outdoor unit and visible, (5) line lengths and sizes match the manufacturer spec (usually uploaded as part of the permit). If anything is out of spec, the inspector issues a re-inspection notice and you have 5 business days to correct it. Plan for 1-2 inspections per project; most pass rough the first time if the contractor is experienced.

Littleton is near the mountains; does elevation affect heat pump sizing?

Yes. Littleton is at 5,360 feet, but the surrounding mountains reach 7,000-10,000 feet. If your home is in the higher foothills (e.g., Littleton's west side near the Palmer Divide), elevation above 6,000 feet reduces heat pump capacity by 5-10% because air density is lower. The Manual J load calculation should account for your specific elevation and outdoor design temperature (Littleton uses -5 to -10°F for heating design). Some contractors mistakenly apply Denver-metro specs (5,280 feet, -10°F) to Littleton homes in elevated areas, leading to undersized systems. Verify your elevation on a topo map and ask the contractor to confirm their Manual J adjustment before signing.

If I buy a heat pump online and hire someone to install it, do I still need a permit?

Yes. The permit requirement is about the installation, not the equipment purchase. If you buy a heat pump from an online retailer or big-box store and hire an installer (licensed or not), Littleton requires a permit. If an unlicensed installer does the work, you pull the permit as owner-builder and must pass Littleton inspections. This is actually risky: most online heat pump sellers do not provide contractor support (condensate line routing, electrical coordination, refrigerant charging), and DIY installation often fails inspection because the condensate line is routed incorrectly or the refrigerant line is too long. Licensed contractors assume the responsibility for passing inspection; you don't. Plan to pay $10,500–$13,500 for a licensed install vs. $6,500–$8,000 for a DIY buy + hire, but the licensed route includes a 5-10 year warranty on labor and eliminates reinspection risk.

Can I convert my furnace to a heat pump without a permit, and claim it's just 'maintenance'?

No. Littleton treats furnace-to-heat-pump conversion as a 'new system' and requires a permit. This is not maintenance; it is a system replacement with new electrical service, backup heat integration, and refrigerant lines. If a home inspector, lender, or insurance company reviews your property and discovers an unpermitted conversion, you will be flagged for a certificate of occupancy hold, refinance denial, or insurance cancellation. The permit fee ($250–$400) is insignificant compared to the cost of legal remedy later.

Does Littleton allow ductless mini-splits, and what's the permit process?

Yes, ductless mini-split heat pumps are permitted in Littleton under the same mechanical-permit category as ducted systems. The process is identical: Manual J load calc, line-run distance verification (most mini-splits max out at 40-50 feet refrigerant run), condensate drain routing, and electrical service confirmation. Littleton has approved numerous Fujitsu, Daikin, and Midea mini-split installations. Permit timeline is 2-3 weeks for new installations (owner-builder or licensed contractor). The outdoor unit must be at least 5 feet from property lines, and the indoor head unit can be mounted on any wall in an occupied room, though inspectors prefer wall-mounted placement over floor/window mounts for condensate drainage. Budget $7,500–$9,500 for a quality single-head mini-split installation in Littleton, including permit and inspections.

What is 'backup heat' and why does Littleton require it for heat pumps?

Backup heat (also called supplemental or auxiliary heat) is a secondary heating source that activates when outdoor temperature drops below the heat pump's effective operating range. In Littleton's 5B climate, heat pumps lose 40-50% capacity below 32°F and become inefficient below 0°F. Backup heat is typically electric resistance strips built into the air handler or a gas furnace (if you kept the old furnace after converting). Littleton requires documentation showing the backup heat type and control strategy (automatic switchover temperature, usually 20-35°F) because undersized heat pumps without backup heat will not maintain comfort and create the perception that heat pumps 'don't work in Colorado.' The permit application must specify the backup source; permits without it are rejected. Electric strip heat is the simplest and cheapest option for new systems. Gas-furnace backup is more expensive but required if you converted from gas and want to keep the furnace as a safety net.

Disclaimer: This guide is based on research conducted in May 2026 using publicly available sources. Always verify current heat pump installation permit requirements with the City of Littleton Building Department before starting your project.