The Short Answer
Yes. Nearly all hurricane retrofit work — roof-to-wall straps, secondary water barriers, impact windows, shutters, garage-door bracing — requires a permit and a licensed wind-mitigation inspection in Jacksonville Beach. Even minor upgrades need plan review and inspection to unlock insurance discounts.
Jacksonville Beach's Building Department enforces Florida Building Code 8th Edition Existing (FBC) with special rigor on High-Velocity Hurricane Zone (HVHZ) requirements because the city sits in coastal Duval County, subject to Design Category C wind speeds (160 mph 3-second gust). What makes Jacksonville Beach different from inland Florida cities: the city's permit portal (managed through the City of Jacksonville Beach Building Department) has a specific 'Wind Mitigation' category that flags retrofits for accelerated review, and the city partners with certified wind-mitigation inspectors (OIR-B1-1802 certified) who pull the insurance-discount inspection at the same time as the final permit inspection — saving you a second inspection trip. Unlike some Florida cities that batch wind-mit reviews quarterly, Jacksonville Beach processes them within 2–4 weeks. The city also cross-references TAS 201 (Miami-Dade Impact-Resistant Shutter Standard) even though TAS 201 is a Miami-Dade spec — any shutter you file must carry the TAS 201 label or equivalent third-party certification, or the city will reject the permit. Finally, Jacksonville Beach's fee structure ($250–$600 depending on retrofit scope) is lower than Miami-Dade or Broward, but the city requires signed proof of secondary water barrier installation (photos of peel-and-stick membrane under shingle starter course) before final sign-off — a detail many homeowners miss and have to re-inspect.

What happens if you skip the permit (and you needed one)

Jacksonville Beach hurricane retrofit permits — the key details

Jacksonville Beach sits in HVHZ (High-Velocity Hurricane Zone) per Florida Building Code Section R301.2.1.1, which means any structural retrofit to resist wind must comply with Design Category C (160 mph 3-second gust). The Florida Building Code 8th Edition Existing (adopted in Jacksonville Beach in 2023) requires that roof-to-wall connections be upgraded from single fasteners to engineered straps — specifically, Florida-approved straps rated for 3-second gust uplift at your design wind speed. When you file a permit with the Jacksonville Beach Building Department, you must submit a wind engineer's design or a pre-approved detail sheet showing the strap spacing (typically every 24–48 inches along the rafter/truss line) and fastener type (galvanized lag bolts minimum). The city's plan reviewer will cross-check your detail against the FBC R301.2.1.1 table (found in the 'Existing Building' chapter, Section 502) and either approve or request clarification on fastener pullout data. Secondary water barriers — the peel-and-stick ice-and-water shield or equivalent membrane laid under the shingle starter course — are now mandatory under FBC Section 505.2.4 because coastal storms drive wind-driven rain horizontally. Many homeowners think this is cosmetic; it is not. The city requires photographic proof (time-stamped, showing the membrane brand) before final sign-off. If you omit it or file plans without it, the permit will be rejected and you must revise and resubmit (30–60 day delay).

Hurricane shutters and impact-rated windows in Jacksonville Beach must carry third-party certification per TAS 201 (Miami-Dade Standard) or equivalent (e.g., ASTM E1886/E1996 large-missile impact). This is unusual: TAS 201 is a Miami-Dade County specification, but Jacksonville Beach's Building Department requires it for any shutter or window filed in the city, because the TAS 201 label proves the product has been tested to Florida's strictest coastal standard. When you obtain a shutter spec from the vendor, look for a label or cert that says 'TAS 201' or 'Meets Miami-Dade Product Approval' — if it only says 'ASTM E1886' or generic 'impact-rated', the permit will be rejected. Common rejection reason: homeowners file shutters that are impact-rated for Miami-Dade Category 2 (75 psi) but not Category 3 (100+ psi), and Jacksonville Beach's Design Category C demands Category 3 (or equivalent). The permit application asks you to upload the manufacturer's TAS 201 cert; if you don't have it, contact the vendor or shutter installer and request the official cert before you file. Garage-door bracing is another mandatory retrofit in HVHZ areas. Your garage door must be braced or replaced with an impact-rated model. If you brace it, you need an engineered brace design (or a manufacturer's pre-approved kit with installation drawings signed by a Florida-licensed engineer) showing the brace type (horizontal, diagonal, or lateral), attachment points, and fastener schedule. The city will check that the brace design matches your Design Category C wind speed; generic 'retrofit kits' bought online without engineering will not pass plan review.

The Jacksonville Beach Building Department's permitting timeline for wind-mitigation work is typically 2–4 weeks from submission to initial review, then 1–2 weeks for revisions if needed. Unlike some Florida counties that require a full structural engineer review, Jacksonville Beach has a streamlined process: if you file a pre-approved retrofit detail (e.g., a standard roof-strap layout or a manufacturer's pre-engineered shutter installation guide), the city's reviewer can approve it over-the-counter — no engineer stamp required. This is a time-saver and a cost-saver (you don't pay for an engineer if you use pre-approved details). However, if your roof framing is non-standard, or if you have a metal roof or a flat roof, the city will flag the permit for an engineer review, adding 2–3 weeks. Fees for Jacksonville Beach wind-mitigation permits range from $250–$600 depending on the scope: a simple shutter retrofit (4–8 shutters, no other work) runs $250–$350; a full roof-to-wall strap upgrade plus shutters plus secondary water barrier might run $500–$600. The fee is based on the 'valuation' of the work — the city estimates this as the labor and materials to complete the retrofit. If your retrofit bid is $8,000, the city will assign a rough valuation of $8,000–$10,000 and calculate the permit fee at roughly 2.5–3% of that figure. You can call the Jacksonville Beach Building Department (located at Jacksonville Beach City Hall) to get a pre-permit fee estimate if you provide a detailed scope of work.

Inspections for hurricane retrofits in Jacksonville Beach follow a three-step sequence: plan review (submittal → approval, 2–4 weeks), in-progress inspection (after sheathing/waterproofing but before final drywall/roof finish), and final inspection. The city can combine the final inspection with a wind-mitigation certification inspection (OIR-B1-1802) if you hire a licensed wind-mitigation inspector from the city's approved roster. The OIR-B1-1802 is the key to insurance savings: this form, signed by a certified inspector, documents roof-to-wall connections, secondary water barriers, garage-door bracing, impact windows/shutters, and roof-cover condition. Homeowners often forget: the permit inspector and the insurance wind-mit inspector are not always the same person. However, in Jacksonville Beach, the city has relationships with local certified inspectors who can do both. Ask the Building Department during plan review: 'Can the final permit inspection be combined with the OIR-B1-1802?' If yes, you schedule one inspection and get both the permit sign-off and the insurance form. If no, you'll need two inspections, adding 1–2 weeks. The OIR-B1-1802, once signed and submitted to your insurance company, typically unlocks a 5–15% annual premium discount, worth $200–$600/year depending on your home's age and coverage. This discount often pays back the retrofit cost in 3–5 years.

Jacksonville Beach homeowners can take advantage of the My Safe Florida Home Program, a state-funded grant program that reimburses 50% (up to $2,500 per home, or up to $10,000 in some areas if you do a full 'fortification' package) for approved wind-mitigation work. Permitted retrofits are eligible for the grant — unpermitted work is not. To apply, you submit your permit number and a signed bid from a contractor to the My Safe Florida Home office; they review your eligibility and send you a reimbursement after work is inspected and signed off. This is a no-brainer if you qualify: it cuts your retrofit cost in half. However, the My Safe Florida Home process has long wait times (6–12 months from application to reimbursement) and requires you to use a contractor from their approved list or meet specific insurance/income thresholds for owner-builder work. Contact the My Safe Florida Home Program (phone: 1-866-MY-SAFE-FL or online through their website) and ask if Jacksonville Beach is currently accepting applications; if yes, get on the list immediately. The program is popular and oversubscribed in coastal Florida, so early application helps. Finally, owner-builders are permitted to do wind-mitigation retrofits themselves under Florida Statutes § 489.103(7), but you cannot pull a permit, hire labor, or sell the home as 'retro'd without a licensed contractor signature unless you live in the home and are the primary owner-builder. This is a Florida-wide rule, not Jacksonville Beach-specific, but it matters: if you want to do the work yourself, you must pull the permit under your name, do all the work yourself (no hired labor except specialty trades like electrical), and you cannot hire a crew. If you hire a contractor, that contractor must pull the permit under their license. Most homeowners hire a contractor anyway because roof work is dangerous and the cost savings of DIY are offset by the liability and permitting complexity.

Three Jacksonville Beach wind / hurricane retrofit scenarios

Scenario A
Roof-to-wall strap retrofit, secondary water barrier, existing asphalt shingles — Northside bungalow, no other changes
You own a 1970s-era single-story bungalow on the north side of Jacksonville Beach (still in HVHZ) with a conventional rafter roof and original asphalt shingles. The roof has no engineered connections — just toe-nails and a few old hurricane straps from a 1990s retrofit. You want to upgrade to modern FBC-compliant roof-to-wall straps (engineered for 160 mph) and add a secondary water barrier under new shingles. This is a straightforward retrofit that Jacksonville Beach sees regularly and approves quickly. You hire a roofer, who obtains a pre-approved strap detail (typically a 1-page drawing from a manufacturer like Strong-Tie or Simpson Strong-Tie) showing strap spacing (every 24 inches along the rafter line, sized for FBC R301.2.1.1 Table 502.11), fastener schedule (e.g., 0.5-inch galvanized lag bolts at the top, hurricane-rated nails at the bottom), and secondary water barrier spec (e.g., ice-and-water shield, Owens Corning or equivalent). The roofer files the permit with the Jacksonville Beach Building Department online (if available) or in person at City Hall. Plan review takes 2 weeks. The roofer performs in-progress inspection (removing old shingles, installing straps and membrane, time-stamped photos), then final inspection by the city. The city's inspector verifies strap spacing, fastener type, and membrane brand; if all matches the approved plan, sign-off happens same day. You can then hire an OIR-B1-1802 licensed inspector (found through your insurance agent or the city's list) to perform a wind-mit inspection and sign the insurance form. Total permit cost: $300–$350. Total retrofit cost (labor + materials): $4,000–$6,000 depending on roof size and shingle grade. Total timeline: 4–6 weeks from filing to final permit sign-off, plus 1–2 weeks for insurance inspection if separate. Insurance savings: 5–10% premium reduction, $200–$400/year.
Permit required | Pre-approved strap detail | FBC R301.2.1.1 compliant | Secondary water barrier (peel-and-stick mandatory) | $300–$350 permit fee | $4,000–$6,000 total retrofit | OIR-B1-1802 inspection recommended | 5–10% insurance discount
Scenario B
Impact-rated hurricane shutters (fixed panel aluminum, TAS 201 certified) on east and south facades, 10 openings — Oceanside oceanfront condo
You own an oceanfront 2-story condo on the beach side of Jacksonville Beach and want to install fixed aluminum hurricane shutters on the 10 windows/doors facing east (ocean) and south (side exposure). The shutters are rated for TAS 201 (Miami-Dade Category 3, 100+ psi impact test, large-missile impact). You select a shutter vendor (e.g., Roll-a-Shield, Gator Shutters, or other local installer), who provides a pre-engineered installation guide with the shutters' TAS 201 cert attached. The vendor includes a detailed layout drawing showing shutter dimensions, fastener locations, and attachment points. You or the vendor files the permit with the Jacksonville Beach Building Department, uploading the installation guide and TAS 201 cert. Crucially: the city will reject the permit if the cert only says 'ASTM E1886' or 'impact-rated' without the TAS 201 label or Miami-Dade Product Approval Number. Most national shutter vendors have TAS 201; local installers may not. Confirm with the vendor before filing. Plan review takes 1–2 weeks (fast, because the design is pre-approved by the manufacturer). In-progress inspection: the city sends an inspector after the shutters are mounted but before fascia/trim is caulked, to verify fastener spacing and anchor point integrity. Final inspection: visual check of all fasteners and proper operation (test opening/closing). No structural engineer needed for standard shutter retrofits. Permit cost: $250–$300. Total shutter cost (material + labor): $6,000–$10,000 depending on shutter type (fixed aluminum is mid-range; motorized or rolling shutters are more). Timeline: 3–5 weeks from filing to final sign-off. Insurance wind-mit inspector can perform OIR-B1-1802 at final inspection. Insurance savings: 10–15% premium reduction, $300–$600/year for oceanfront condo (higher savings than inland homes due to higher risk rating). Tip: if your condo is in a historic district (check with the city), you may need Historic Preservation Board approval before installing shutters, which adds 2–4 weeks. Check this BEFORE hiring a contractor.
Permit required | TAS 201 certification mandatory | Pre-engineered installation guide required | $250–$300 permit fee | $6,000–$10,000 shutters + installation | 3–5 weeks timeline | 10–15% insurance discount possible | Historic district approval may apply
Scenario C
Garage-door bracing retrofit (existing single-car door, non-impact-rated) plus engineered brace kit — Riverside neighborhood, new construction adjacent (no secondary water barrier work)
Your Riverside-area home has an older, single-car overhead garage door with no impact resistance. A new development is going up next door and the city is pushing residents to retrofit for hurricane risk. You decide to install an engineered garage-door brace kit (e.g., a proprietary diagonal or lateral brace system) rather than replace the door (which costs $1,500–$2,500). The brace kit includes a pre-engineered design stamped by a Florida-licensed engineer, showing the brace type, attachment points (header, sill, jamb), fastener schedule, and load rating (must meet FBC Design Category C, 160 mph). You or a contractor files the permit with the Jacksonville Beach Building Department, uploading the engineer-stamped brace design. The city reviews the design against FBC Section 424.3.1 (Garage Door Protection); if the design is stamped and complete, approval is fast (1–2 weeks). In-progress inspection: the city verifies fastener holes drilled correctly, anchors installed in correct locations (concrete fasteners into concrete, lag bolts into wood framing), and brace alignment square. Final inspection: proof that brace is operational (manual test of garage-door opening/closing under brace load). Permit cost: $200–$250 (lowest-cost wind-mitigation retrofit). Brace kit cost: $800–$1,500 (material + labor for installation). Total timeline: 3–4 weeks. Insurance savings: 3–5% premium reduction (lower than roof/shutter retrofits, but still valuable), $100–$200/year. Important caveat: some insurance companies offer bigger discounts if you combine garage-door bracing with roof straps or shutters — ask your agent if bundling retrofits unlocks a higher discount tier. Also note: if you ever decide to replace the garage door in the future, an impact-rated door (e.g., DASMA-rated or TAS 201) eliminates the need for bracing and is a permanent solution, though costlier upfront.
Permit required | Pre-engineered design (Florida PE stamp) | FBC Section 424.3.1 compliant | $200–$250 permit fee | $800–$1,500 brace kit + labor | 3–4 weeks timeline | 3–5% insurance discount | Can be bundled with roof/shutter retrofits for higher discount

Every project is different.

Get your exact answer →
Takes 60 seconds · Personalized to your address

Design Category C and HVHZ: Why Jacksonville Beach is stricter than inland Florida

Jacksonville Beach's coastal location also means secondary water barriers are non-negotiable. The city sits on the Atlantic coast, and wind-driven rain in hurricanes is brutal — rain comes sideways and upward, working under shingles and into rafter cavities. The FBC Section 505.2.4 requirement for an ice-and-water shield or equivalent peel-and-stick membrane under the shingle starter course is not optional in Jacksonville Beach; the city has seen too many post-hurricane water leaks in homes without it. When you file a retrofit permit that includes re-shingling, the city will ask to see the membrane spec (brand, thickness, coverage area). Some inspectors require photos during construction showing the membrane installed before shingles go on — if you skip this or try to shortcut it, the permit will not be signed off. Cost of secondary water barrier: roughly $0.50–$1.00 per sq. ft., so a 2,000 sq. ft. roof might run $400–$800 in material + labor. Small cost, big compliance impact.

The OIR-B1-1802 insurance inspection: unlocking the discount and linking retrofit to permit sign-off

To get an OIR-B1-1802 inspection, you hire a licensed wind-mitigation inspector from a list provided by your insurance agent or found through the Florida Department of Financial Services website. The inspector visits your home after the permitted retrofit is complete, photographs the retrofits, completes the OIR-B1-1802 form, and submits it to your insurer. Cost: $150–$300 depending on the inspector and the home size. Timeline: typically 1–2 weeks to schedule after final permit sign-off. The inspection is straightforward — the inspector photographs roof straps, water barrier, shutters, garage-door brace, and roof condition, then fills out the form. Most inspectors bundle the inspection into a 1–2 hour visit. If you schedule the inspection immediately after final permit sign-off, you can submit the form to your insurer within 30 days and start receiving the discount on your next premium renewal.

City of Jacksonville Beach Building Department
11 North First Street, Jacksonville Beach, FL 32250 (City Hall building; exact permit office location varies; call ahead)
Phone: (904) 247-6000 (main line; ask for Building Department or Permits) | https://www.jaxbeachfl.gov/ (check for online permit portal or PermitSoft/Accela link)
Monday–Friday, 8:00 AM–5:00 PM (verify before visiting)

Common questions

Can I install hurricane shutters myself without a contractor?

Yes, under Florida Statutes § 489.103(7), you can pull a permit and install shutters yourself if you live in the home and are the primary owner. However, you must pull the permit under your name, submit the shutter specs and TAS 201 cert, and pass the city's final inspection. You cannot hire labor or subcontractors; all work must be yours. Most homeowners hire a contractor because shutter installation (drilling into masonry or metal framing, fastening through concrete) is technically challenging and has liability risk. If you DIY, you save roughly 40–50% of the cost ($1,500–$2,500 labor), but you take on the liability and the inspection risk. Do not attempt this unless you are confident in your fastening skills and have the right fasteners (stainless-steel or hot-dip galvanized anchors, not standard hardware-store fasteners).

Do I need a structural engineer stamp for a roof-to-wall strap retrofit?

Not always. Jacksonville Beach Building Department allows pre-approved retrofit details that do not require an engineer stamp. If you use a manufacturer's pre-engineered detail (e.g., Simpson Strong-Tie's standard strap layouts for FBC Design Category C) and provide the manufacturer's spec sheet and design guide, the city can approve the retrofit over-the-counter without an engineer review. However, if your roof is non-standard (metal, flat, unusual framing, or rafter spacing wider than 24 inches), the city will require a structural engineer to design the strap layout and provide a signed stamp. Cost of engineer design: $500–$1,500 depending on complexity. Timeline: add 2–3 weeks for engineer review. Always ask the city's plan reviewer during permit intake: 'Does my roof framing allow a pre-approved detail, or do I need an engineer stamp?' This saves time and cost if you can use a pre-approved detail.

Can I do a roof retrofit without pulling a permit if I am just replacing shingles, not touching the straps or structure?

No. Any roof work in Jacksonville Beach HVHZ area requires a permit, even shingle replacement, because the city wants to verify that the secondary water barrier is installed and the roof is properly secured. Florida Building Code Section 101.2 states that any work 'affecting the structural strength or safety' of a building requires a permit, and roof work (including re-shingling in an HVHZ) falls into this category. If you pull a shingle-replacement permit without the water barrier upgrade, the permit will likely be flagged for upgrade during plan review. The city is strict about this because post-hurricane inspections have found that homes with old roofs and no water barrier suffer catastrophic interior damage. Always include secondary water barrier in your shingle-replacement scope and mention it in the permit application. If you are just replacing a few missing shingles (cosmetic repair, not full replacement), you might not need a permit; call the Building Department to ask about the threshold for 'minor repair' before you start work.

What if the city rejects my permit plan for not meeting HVHZ requirements?

If Jacksonville Beach Building Department rejects your permit (e.g., shutters without TAS 201 cert, roof straps not designed for Design Category C, garage-door brace without engineer stamp), you have two paths: (1) revise the plans to comply and resubmit, or (2) appeal the rejection to the city's plan review manager or Building Official if you believe the rejection is incorrect. Revision is faster: contact your contractor or designer, explain the deficiency, revise the spec or design, and resubmit. The city will re-review at no additional fee (usually) within 1–2 weeks. Appeal is slower and adversarial; avoid it unless you have a strong reason to believe the reviewer made an error. Most rejections are legitimate — missing TAS 201 cert, wrong fastener type, strap spacing too wide. Address the deficiency and resubmit. Typical resubmit turnaround: 1–2 weeks. Budget an extra month into your timeline if you anticipate a rejection.

Does the My Safe Florida Home grant cover my retrofit, and how long does it take?

Yes, if you are a homeowner in Florida (including Jacksonville Beach) and meet income thresholds (varies; roughly 250–300% of federal poverty level), you can apply for the My Safe Florida Home Program grant, which reimburses 50% of approved wind-mitigation work up to $2,500 (or $10,000 if you do a full 'fortification' package with roof cover, straps, and water barrier). To qualify, your retrofit work must be permitted and inspected by the local building department. Timeline: application to approval takes 6–12 months, and reimbursement comes after final inspection sign-off. If you apply now, you will likely not receive reimbursement until late 2024 or 2025. The program is oversubscribed in coastal Florida, so early application is critical. Contact My Safe Florida Home at 1-866-MY-SAFE-FL or visit their website to check Jacksonville Beach's current enrollment status and income limits. If you qualify and can wait, the grant cuts your retrofit cost in half — a major financial incentive.

Will Jacksonville Beach require a survey or homeowner's certification that the work was done correctly?

No survey required. Jacksonville Beach Building Department relies on the permit inspector's final sign-off and the contractor's signed affidavit (on the permit application) that all work was done per code. The city does not require a third-party survey or homeowner certification. However, if you are using the retrofit for an insurance discount, the wind-mitigation inspector's OIR-B1-1802 form serves as your 'proof' that the retrofits meet insurance standards. Keep copies of the OIR-B1-1802, the final permit sign-off, and the contractor's warranty documentation in your home file for future reference (e.g., if you sell or if you file an insurance claim).

Can I do a retrofit in stages, or do I have to file all the work in one permit?

You can file in stages. If you want to do roof straps this year and shutters next year, you pull two separate permits. However, each permit has its own plan review, inspection, and fee. There is no bulk discount for doing multiple retrofits in a single permit application; in fact, bundling them can delay approval because the city will review all work comprehensively. Best practice: prioritize your retrofits based on insurance savings and cost. Roof-to-wall straps typically give the highest discount per dollar spent, so do those first. Then shutters. Then garage-door bracing. Each retrofit gets its own permit cycle (2–4 weeks each), so a full multi-stage retrofit can take 3–6 months total. The wind-mitigation insurance inspection (OIR-B1-1802) is done once after all retrofits are complete, not after each stage.

Is Jacksonville Beach in a historic district, and does that affect my retrofit permit?

It depends on your property. Jacksonville Beach has historic preservation overlays in a few neighborhoods (e.g., parts of downtown and some older beach-community areas). If your home is in a historic district, you may need to submit your retrofit plans to the Historic Preservation Board or receive approval from the city's Design Review Committee before filing a building permit. This is separate from the building permit and adds 4–8 weeks to the timeline. Check with the Jacksonville Beach Building Department or City Planner when you get your property address — they will tell you instantly if your home is in a historic district. If yes, you will be directed to contact the Historic Preservation Board before you pull a building permit. Hurricane shutters, in particular, are scrutinized in historic areas because they can alter the facade appearance. Interior or hidden retrofits (roof straps, secondary water barrier, garage-door bracing) typically do not require historic approval. Confirm before you hire a contractor.

What is the difference between a roof-to-wall strap and a hurricane tie, and do I need the newer version?

A 'hurricane tie' is an older term for a roof-to-wall connection; modern straps are engineered versions of the same concept. Old hurricane ties (pre-2000) were often simple metal angles with 2–3 nails — insufficient for modern Design Category C wind speeds. Modern straps (Simpson Strong-Tie LUS, LHUS, etc.) are engineered to distribute load across multiple fasteners (typically 6–8) and are rated for specific pullout forces (e.g., 2,000+ lbs). Jacksonville Beach Building Department requires modern engineered straps per FBC Section R301.2.1.1; old-style ties will not pass inspection if you are doing a new retrofit. If your home already has 1990s-era hurricane ties, a retrofit might upgrade to modern straps (which increases the fastener count and spacing) or might work around the existing ties if they are still sound and the engineer deems them compliant. Always specify to your contractor or engineer: 'Use modern FBC-compliant straps, not old-style ties.' Modern straps are readily available from roofing suppliers and are not significantly more expensive.

If I hire a contractor, can they use an owner-builder exemption so I save on permit fees?

No. The owner-builder exemption under Florida Statutes § 489.103(7) applies only if YOU do the work yourself. If you hire a contractor, the contractor must pull the permit under their contractor's license, and no exemption applies. The permit fee is based on the work scope, not on who does it. Do not attempt to fraudulently claim owner-builder status if you are hiring labor; the city will flag this during inspection and may deny the permit or impose penalties. The exception: you can hire specialty trades (e.g., a licensed electrician to run new outlet for a shutter motor) and still claim owner-builder for the shutter installation itself, as long as you do the installation. This is a gray area; if you are considering it, call the Building Department and describe your scenario before you file.